Home  >  Products  >  Transformer  >  Oil Immersed Transformer

20kV Oil Immersed Power Transformer

Overview

The oil immersed power transformer is composed of core, coil, voltage regulating switch, oil tank and other components, and the dielectric material is dielectric oil.


Download:

SOJO Transformer Brochure.pdf

Description


 The oil immersed power transformer is used for regulating voltage and AC power transmission. The advantages include small dimension, reasonable price, strong weather resistance and so on. It is applicable to power systems, industrial and mining enterprises, transportation, post and telecommunications sector, research institutes, etc. A variety of transformers under 110kV are included in the product line: the stacked iron core structure series, the rolled iron core structure series, amorphous alloy series, etc. Smart and diverse structures and nice appearance make this product to meet the needs of different users.


Model Explaination



Features:


Core

High-quality grain-oriented cold-rolled silicon steel sheet are employed, and the whole oblique non-porous banding structure are used here. The core has a multi-level ladder shape, with three joints or five joints, which is of low no-load loss and low noise. Rolled cores are direct rolled by certain special equipment, which gives the advantages including no seam, no corner weight, reluctance reduction, low no-load loss. Amorphous alloy is an advanced core material, which leads to an average reduction of 72% no-load loss and a reduction of 50% no-load current.


Coil

The high-quality QQ acetal enameled round copper wire and oxygen-free copper rod are used to form the coil. The coil type includes cylinder type, continuous type, new type spiral type, split type, etc. It has sufficient electrical strength, mechanical strength and cooling capacity.

In order to increase the capacity of anti-short-circuit of the transformer, self-adhesive transposition wire is used in the 35kV and above windings. The wire is made of self-adhesive acetal enameled flat wire, and after winding into a coil, it is heated so that the flat wire could be bonded between each other to form a rigid coil, which can withstand greater bending stress, thereby enhancing the capacity of anti-short-circuit of the transformer. The most important feature of the self-adhesive transposition wire is that it can reduce the loss of the transformer, and as a result of multi-stranded conductor with transposition, the eddy current loss and circulation loss are greatly reduced, it can also reduce the temperature rise of the partial hot spots of winding, thus the winding temperature distribution is more uniform.


Oil tank 

The oil tank is made of high quality steel plate, and the shape includes elliptical shape, rectangular shape, etc. The type of the radiator includes: corrugated sheet type radiator, expansion type radiator and corrugated type tank. The sealing performance test is conducted on oil tanks. The inside and outside surfaces are pickling and phosphate treated, and then spray priming paint for three times and surface paint for one time, which give its corrosion resistance.


Normal service condition

Ambient air temperature

Maximum temperature: +40℃

Minimum temperature: -45℃

Average temperature of the warmest month: +30℃

The hottest annual average temperature: +20℃

Altitude: ≤ 1000m

Contamination class: III;

Seismic intensity: VIII

Power supply voltage waveform: approximately sinusoidal;


Note: If the above conditions are exceeded, please specify when ordering, for special consideration.


Parameters

S11 20kV Three Phase Oil Immersed Natural Air Cooling Double Winding Off Circuit Tap Changing Distribution Transformer



Model Rated Capacity(kVA) Voltage (kV) Vector Group Impedance Voltage(%) Total Weight(t) Reference Dimensions(mm)
L*W*H
No-load Loss (W) Load Loss (W)
S11-30/20 30 High Voltage H.V. 
20
±2×2.5% 
±5% 
Low VoltageL.V. 
0.4 
Dyn11
Yyn0
4 0.9 1200*950*1400 100 690/660
S11-50/20 50 1 1200*950*1500 130 1010/960
S11-63/20 63 1.1 1200*950*1500 150 1200/1150
S11-80/20 80 1.2 1200*950*1600 180 1440/1370
S11-100/20 100 1.4 1300*1000*1750 200 1730/1650
S11-125/20 125 1.6 1400*1100*1800 240 2080/1980
S11-160/20 160 1.7 1450*1200*1850 290 2540/2420
S11-200/20 200 1.8 1500*1300*1900 340 3000/2860
S11-250/20 250 2 1600*1500*2000 400 3520/3350
S11-315/20 315 2.2 1800*1600*2100 480 4210/4010
S11-400/20 400 2.4 1900*1700*2200 570 4970/4730
S11-500/20 500 2.7 2000*1800*2300 680 5940/5660
S11-630/20 630 4.5 3 2150*2000*2350 810 6820
S11-800/20 800 3.4 2250*2050*2400 980 8250
S11-1000/20 1000 4 2400*2200*2450 1150 11330
S11-1250/20 1250 4.5 2500*2300*2500 1380 13200
S11-1600/20 1600 5 2600*2400*2600 1660 15950
S11-2000/20 2000 5.6 2700*2450*2700 1950 19140
S11-2500/20 2500 7.1 2850*2650*2800 2340 22220



S13 20kV Three Phase Oil Immersed Natural Air Cooling Double Winding Off Circuit Tap Changing Distribution Transformer



Model Rated Capacity(kVA) Voltage (kV) Vector Group Impedance Voltage(%) Total Weight(t) Reference Dimensions(mm)
L*W*H
No-load Loss (W) Load Loss (W)
S13-30/20 30 High Voltage H.V. 
20
±2×2.5% 
±5% 
Low Voltage L.V. 
0.4 
Dyn11
Yyn0
4 0.9 1200*950*1400 80 690/660
S13-50/20 50 1 1200*950*1500 100 1010/960
S13-63/20 63 1.1 1200*950*1500 110 1200/1150
S13-80/20 80 1.2 1200*950*1600 130 1440/1370
S13-100/20 100 1.4 1300*1000*1750 150 1730/1650
S13-125/20 125 1.6 1400*1100*1800 170 2080/1980
S13-160/20 160 1.7 1450*1200*1850 200 2540/2420
S13-200/20 200 1.8 1500*1300*1900 240 3000/2860
S13-250/20 250 2 1600*1500*2000 290 3520/3350
S13-315/20 315 2.2 1800*1600*2100 340 4210/4010
S13-400/20 400 2.4 1900*1700*2200 410 4970/4730
S13-500/20 500 2.7 2000*1800*2300 480 5940/5660
S13-630/20 630 4.5 3 2150*2000*2350 570 6820
S13-800/20 800 3.4 2250*2050*2400 700 8250
S13-1000/20 1000 4 2400*2200*2450 830 11330
S13-1250/20 1250 4.5 2500*2300*2500 970 13200
S13-1600/20 1600 5 2600*2400*2600 1170 15950
S13-2000/20 2000 5.6 2700*2450*2700 1390 19140
S13-2500/20 2500 7.1 2850*2650*2800 1650 22220


SH15 20kV Three Phase Oil Immersed Natural Air Cooling Double Winding Off Circuit Tap Changing Distribution Transformer With Amorphous Alloy Core


Model Rated Capacity(kVA) Voltage (kV) Vector Group Impedance Voltage(%) Total Weight(t) Reference Dimensions(mm)
L*W*H
No-load Loss (W) Load Loss (W)
SH15-30/20 30 High Voltage H.V.
20
±2×2.5%
±5%
Low Voltage L.V.
0.4
Dyn11
Yyn0
5.5 0.7 1100*1100*650 40 690/660
SH15-50/20 50 0.8 1200*1100*650 55 1010/960
SH15-63/20 63 0.95 1300*1250*650 65 1200/1150
SH15-80/20 80 1 1400*1300*700 75 1440/1370
SH15-100/20 100 1.25 1450*1300*850 90 1730/1650
SH15-125/20 125 1.3 1450*1300*950 100 2080/1980
SH15-160/20 160 1.4 1450*1300*1000 120 2540/2420
SH15-200/20 200 1.5 1500*1300*1100 145 3000/2860
SH15-250/20 250 1.7 1600*1350*1150 165 3520/3350
SH15-315/20 315 1.9 1700*1350*1200 200 4210/4010
SH15-400/20 400 2.2 1800*1400*1200 240 4970/4730
SH15-500/20 500 2.5 1900*1500*1200 290 5940/5660
SH15-630/20 630 6 3 2000*1600*1300 370 6820
SH15-800/20 800 3.5 2100*1700*1400 450 8250
SH15-1000/20 1000 4 2200*1800*1500 530 11330
SH15-1250/20 1250 5 2300*1900*1600 620 13200
SH15-1600/20 1600 6 2600*2000*1700 750 15950
SH15-2000/20 2000 7.5 2900*2200*1900 900 19140
SH15-2500/20 2500 9.5 3000*2500*2000 1080 22220