20kV Dry Type Transformer

Overview

SC (B) 10/11 epoxy cast dry-type transformer is a dry-type transformer with strong mechanical strength, electrical strength, and good heat-resistance performance. It is made of F class epoxy resin mixture with filler, and after vacuum film degassing, the mixture is cast onto the glass fiber formed net frame to enhance the mechanical strength, electrical strength, and heat-resistance performance.


Download:

SOJO Transformer Brochure.pdf


Description

This type of transformer is an excellent product for urban power network transformation, which is very suitable for urban power grid, high-rise buildings, business centers, theaters, hospitals, hotels, tunnels, subway, underground power stations, laboratories, stations, terminals, airports, Pad-mounted substation, explosion prevention and explosion proof in urban power network, high-rise buildings, business center, theaters, hospitals, hotels, tunnels, subways, underground power stations, laboratories, railway stations, docks, airports and Pad-mounted substations, etc, which need high level of retardant, anti-explosion, anti-moisture performances.


Model Explanation



Features

  • Strong anti-short-circuit ability, low loss, low no-load current, strong impact resistance capability, low partial discharge, low noise, good heat sinking capacity.

  • Performance parameters are better than GB and IEC standards.。

  • Safe, flame retardant, fireproof, non-polluting, it can be installed directly in the load site.

  • Maintenance-free, easy to install, low operating costs.

  • High reliability, high mechanical strength.。

  • Good seismic capability.

  • Good anti-moisture & anti-corrosion features.

  • Good overload capability, in the absence of air-cooling, it can withstand 120% of the load long-term service.

  • Suitable to: substations located in densely populated, narrow urban places.


Normal service conditions 

Altitude: ≤1000m

Ambient air temperature: 

Maximum temperature: +40℃

Minimum temperature: -25℃ (Outdoor dry type power transformer)

Minimum temperature: -5℃ (Indoor dry type power transformer)

Highest average temperature of month: +30℃

Highest average temperature of year month: +20℃

Relative air humidity: ≤90%,There should not be water on the coil surface;

Three-phase power supply voltage of three-phase transformer should be approximately symmetrical 

Power supply voltage wave should be similar to sine wave.


Parameters

20KV

SC(B)10 Three Phase Epoxy Resin Cast Dry Type Power Transformer

Model Rated
Capacity
(kVA)
Voltage
(kV)
Vector
Group
No-load
Loss
(W)
Load
Loss
(W)
Weight
(kg)
Reference
Dimensions
(mm)L*W*H
Enclosure
Dimensions
(mm)L*W*H
Total
Weight
(kg)
Impedance
Voltage High
Voltage(%)
High
Voltage
(%)H.V.
Low
Voltage
L.V.
SC10-50 50 20,22
24
±2×
2.5%
0.4 Dyn11
Yyn0
340 1230 600 1050*700*950 1600*1300*2200 800 6
SC10-100 100 540 1990 900 1100*700*1200 1600*1300*2200 1100
SC10-160 160 670 2470 1100 1200*800*1200 1600*1300*2200 1300
SC10-200 200 730 2940 1200 1250*800*1250 1800*1350*2200 1400
SC10-250 250 840 3420 1500 1300*800*1280 1800*1350*2200 1700
SC10-315 315 970 4080 1700 1400*940*1280 1800*1350*2200 1950
SC(B)10-400 400 1150 4840 1800 1450*940*1300 2000*1400*2200 2050
SC(B)10-500 500 1350 5790 2200 1450*940*1340 2000*1400*2200 2450
SC(B)10-630 630 1530 6840 2250 1500*940*1480 2000*1400*2200 2500
SC(B)10-800 800 1750 8260 2500 1540*940*1510 2150*1450*2200 2750
SC(B)10-1000 1000 2070 9780 2940 1580*940*1730 2150*1450*2200 3200
SC(B)10-1250 1250 2380 11500 3290 1580*940*1760 2300*1500*2200 3800
SC(B)10-1600 1600 2790 13800 4240 1860*1190*1800 2400*1550*2200 4550
SC(B)10-2000 2000 3240 16300 5200 1910*1190*1900 2600*1600*2200 5500
SC(B)10-2500 2500 3870 19300 6020 2000*1190*2000 2600*1600*2200 6400